카테고리 보관물: Filter

49023

Chroma Filter 49023

49023 Spectrum

FiltersType
ET500/40xEX
 T525lpxrBS
ET560/50mEM

– Filter set for AlexaFluor 514/ZsYellow/Eosin

Excitation (㎚)Emission (㎚)
517539

Spectrum Comparison Fluor and 49023

AlexaFluor 514 VS 49023
AlexaFluor 514 VS 49023

Best with these fluorochromes

49023 Spec

  • Typical Application(s) : Widefield Microscopy
  • Coating : Sputter/Hard Coated
  • Round excitation and emission filters mounted in anodized aluminum rings 2.3mm thick, up to 25mm in diameter
  • Rectangular dichroics up to 26x38mm, 1mm thick, to fit standard microscope manufacturer filter cubes

49910

Chroma Filter 49910

49910 Spectrum

Chroma_49910
Chroma_49910
FiltersType
ZET561/10xEX
 ZT514rdcBS
ET630/70mEM

– Filter set of 561nm Laser Bandpass Set for AlexaFluor 568, AlexaFluor 594, Texas Red®, mCherry

For use with lasers between 557-563㎚

Excitation (㎚)Emission (㎚)
587610

Spectrum Comparison Fluor and 49910

mCherry VS 49910
mCherry VS 49910

49910 Spec

  • Typical Application(s) : Laser (Non-TIRF)
  • Coating : Sputter/Hard Coated
  • Round excitation and emission filters mounted in anodized aluminum rings 2.3mm thick, up to 25mm in diameter
  • Rectangular dichroics up to 26x38mm, 1mm thick, to fit standard microscope manufacturer filter cubes

49915

Chroma Filter 49915

49915 Spectrum

Chroma_49915
Chroma_49915
FiltersType
ZET365/20xEX
 ZT365bcmBS
ET425lpEM

– Filter set of 355-375nm Laser Longpass Set for Uncaging and Ablation

Excitation (㎚)Emission (㎚)
346442

Spectrum Comparison Fluor and 49915

AlexaFluor 350 VS 49915
AlexaFluor 350 VS 49915

49915 Spec

  • Typical Application(s) : Widefield Microscopy
  • Coating : Sputter/Hard Coated
  • Round excitation and emission filters mounted in anodized aluminum rings 2.3mm thick, up to 25mm in diameter
  • Rectangular dichroics up to 26x38mm, 1mm thick, to fit standard microscope manufacturer filter cubes

19004

Chroma Filter 19004

Download Catalog_19004

19004 Spectrum

FiltersType
AT540/25xEX
AT565DCBS
AT575lpEM

– Filter set for TRITC/Cy3 Longpass

  • Main Fluorochromes : TRITC
Excitation (㎚)Emission (㎚)
555580

Spectrum Comparison Fluor and 19004

TRITC  VS JNO-G(L)
TRITC VS JNO-G(L)_Chroma 19004

Best with these fluorochromes

  • R-phycoerythrin

19004 Spec

  • Typical Application(s) : Widefield Microscopy
  • Coating : Sputter/Hard Coated
  • Round excitation and emission filters mounted in anodized aluminum rings 2.3mm or 3.5mm thick, up to 25mm in diameter
  • Rectangular dichroics up to 26x38mm or 25.5×36, 1mm thick, to fit standard microscope manufacturer filter cubes

19002

Chroma Filter 19002

19002 Spectrum

JNO-B(L) Spectrum
FiltersType
AT480/30xEX
 AT505DCBS
AT515lpEM

– Filter set for GFP/FITC Longpass

  • Main Fluorochromes : FITC
Excitation (㎚)Emission (㎚)
490525

Spectrum Comparison Fluor and 19002

FITC VS 19002
FITC VS 19002 spectra-viewer

Best with these fluorochromes

  • Acridine Orange + DNA and RNA
  • Auramine-rhodamine
  • JC-1 non-ratiometric

19002 Spec

  • Typical Application(s) : Widefield Microscopy
  • Coating : Sputter/Hard Coated
  • Round excitation and emission filters mounted in anodized aluminum rings 2.3mm or 3.5mm thick, up to 25mm in diameter
  • Rectangular dichroics up to 26x38mm or 25.5×36, 1mm thick, to fit standard microscope manufacturer filter cubes

19000

Chroma Filter 19000

19000 Spectrum

Blue Excitation, Long Pass Emission
JNO-B(L) Spectrum
FiltersType
AT375/28xEX
AT415DCBS
AT435lpEM

– Filter set for UV/DAPI Longpass

  • Main Fluorochromes : DAPI
Excitation (㎚)Emission (㎚)
359461

Spectrum Comparison Fluor and 19000

DAPI VS JNO-U(B)

Best with these fluorochromes

  • Calcofluor White
  • DAPI

19000 Spec

  • Typical Application(s) : Widefield Microscopy
  • Coating : Sputter/Hard Coated
  • Round excitation and emission filters mounted in anodized aluminum rings 2.3mm or 3.5mm thick, up to 25mm in diameter
  • Rectangular dichroics up to 26x38mm or 25.5×36, 1mm thick, to fit standard microscope manufacturer filter cubes

39007

Chroma Filter 39007

39007 Spectrum

Chroma_39007
Chroma_39007
FiltersType
 AT620/50xEX
AT655DCBS
AT690/50mEM

– Filter set for Cy5/AlexaFluor 647/Draq5

  • Main Fluorochromes : Cy5
Excitation (㎚)Emission (㎚)
649670

Spectrum Comparison Fluor and 39007

Cy5 VS 39007
Cy5 VS 39007

Best with these fluorochromes

39007 Spec

  • Typical Application(s) : Widefield Microscopy
  • Coating : Sputter/Hard Coated
  • Round excitation and emission filters mounted in anodized aluminum rings 2.3mm or 3.5mm thick, up to 25mm in diameter
  • Rectangular dichroics up to 26x38mm or 25.5×36, 1mm thick, to fit standard microscope manufacturer filter cubes

39010

JNOPTIC Filter 39010

Download Catalog_39010

39010 Spectrum

Chroma_39010
Chroma_39010
FiltersType
AT560/40xEX
AT600DCBS
AT635/60mEM

– Filter set for Texas Red/mCherry/AlexaFluor 594

Excitation (㎚)Emission (㎚)
590617

Spectrum Comparison Fluor and 39010

Alexa Fluor 594 VS 39010
Alexa Fluor 594 VS 39010
mCherry VS 39010
mCherry VS 39010

Best with these fluorochromes

39010 Spec

  • Typical Application(s) : Widefield Microscopy
  • Coating : Sputter/Hard Coated
  • Round excitation and emission filters mounted in anodized aluminum rings 2.3mm thick, up to 25mm in diameter
  • Rectangular dichroics up to 26x38mm, 1mm thick, to fit standard microscope manufacturer filter cubes

39004

Chroma Filter 39004

39004 Spectrum

FiltersType
AT540/25xEX
AT565DCBS
AT605/55mEM

– Filter set for TRITC/Cy3/TagRFP/AlexaFluor546

  • Main Fluorochromes : TRITC
Excitation (㎚)Emission (㎚)
555580

Spectrum Comparison Fluor and 39004

Best with these fluorochromes

39004 Spec

  • Typical Application(s) : Widefield Microscopy
  • Coating : Sputter/Hard Coated
  • Round excitation and emission filters mounted in anodized aluminum rings 2.3mm or 3.5mm thick, up to 25mm in diameter
  • Rectangular dichroics up to 26x38mm or 25.5×36, 1mm thick, to fit standard microscope manufacturer filter cubes

39002

Chroma Filter 39002

39002 Spectrum

Chroma_39002
Chroma_39002
FiltersType
AT480/30xEX
 AT505DCBS
AT535/40mEM

– Filter set for EGFP/FITC/Cy2/AlexaFluor488

  • Main Fluorochromes : FITC
Excitation (㎚)Emission (㎚)
490525

Spectrum Comparison Fluor and 39002

FITC VS 39002
FITC VS 39002

Best with these fluorochromes

39002 Spec

  • Typical Application(s) : Widefield Microscopy
  • Coating : Sputter/Hard Coated
  • Round excitation and emission filters mounted in anodized aluminum rings 2.3mm or 3.5mm thick, up to 25mm in diameter
  • Rectangular dichroics up to 26x38mm or 25.5×36, 1mm thick, to fit standard microscope manufacturer filter cubes